MMU measures: The efficacy of any pump or compressor. (Using current coils - noninvasive).

Pump/Compressor Measurements Specifications (Current Coil Per phase) -Three Channels.

Measurement Range

0-100 A Max

Measurement Resolution 

0.1 A

Measurement Accuracy 

± 1A

Current Coils Specifications

Inner diameter

24mm

Dielectric Withstanding Voltage(Hi-pot)

2.5KV/1mA/1min

Impulse Withstand Voltage

5KV Peak

Insulation Resistance

DC500V/100MΩ min

Approx. Weight

85 gm

Interface & Powering of MMU* Specifications

Interface to Main Board

RS-485

Power

24 volt – Internally form Main Board

Indicators

Two LEDS (Online ,Alarm)

Selectable address

7 Dip switches

USB type C 

Transfer instantaneous data using Jason format


Powering unit using USB pins(5VDC)

Environmental& Mechanical Specifications

Enclosure

ABS Plastic

Operating Temperature

0-50 °C

Storage Temperature

-20 - 60°C

Relative Humidity

0-95% RH

Dimensions

104 x 92 x 42 mm

Weight

100 g + (85/coil)