Why engineers choose the Panel Mount — Compact
Same board, lower cost per point
The Standard's AC and DC measurement without the touchscreen — the data goes to the cloud dashboard instead.
Powered from the panel
Runs from an external 24 V DC / 2.5 A supply, a voltage common in control panels.
Fleet-ready
Specify it once and install it across many panels, sites or chargers with the same configuration.
Still able to act
Two digital inputs and two relay outputs, like the Standard.
Specifications
| AC power quality | 0–630 V RMS; 2nd channel with the optional external module |
|---|---|
| DC power quality | 1 channel, 0–630 V DC, 125 kSPS |
| Earth measurement | With the optional PQ+RE module |
| Event classification | Dips, swells, interruptions, transients, RVC, frequency variation, inrush current, phase sequence — classified per IEC 61000-4-30 |
| Event capture | 5 cycles of waveform before and after every event |
| Parameters | RMS V and I, THD, harmonic amplitude and phase, interharmonics, unbalance, flicker (Pst, Plt), true and displacement power factor, K-factor, active / reactive / apparent power and energy |
| Digital I/O | 2 × digital input 0–30 V DC · 2 × relay output 1 A |
| Display | None (cloud dashboard) |
| Power input | External 24 V DC / 2.5 A |
| Battery | Optional, 3 hours |
| Ports | 2 × RS-485 · 3 × USB |
| Processor | Quad-core ARM Cortex-A72, 1.5 GHz · 2 GB RAM · 16 GB flash |
| Storage | SD card 32 GB, expandable to 256 GB |
| Network | 2 × Gigabit Ethernet (one internet, one local) |
| Protocols | Modbus, BACnet, DNP3, IEC 61850, MQTT, SNMP, IEC 62056, HTTP/HTTPS, email |
| Alerts & data | Cloud dashboard, SMS / email / app alerts, export to PDF, CSV and JSON |
| Operating temperature | 0–60 °C |
| Part number | BB0205A010 |
From the PowerWadi datasheet. Download the full datasheet for drawings, sensor options and certificates.
Where it is used
- Fleets of EV chargers or inverters
- Telecom and remote sites
- Distribution boards across a large building
- OEM equipment that ships with monitoring
How it is priced
Inspector is quoted per project rather than from a price list, because the cost depends on the model, the number of measurement points, the sensors and clamps you need, and whether you want the cloud dashboard and alerts. Tell an engineer what you need to measure and you get a quote for that configuration. For how analyzers are priced across the market, read what a power quality analyzer costs.
Made in Egypt, supported worldwide
Inspector is designed and built by PowerWadi in Sheikh Zayed, Giza. Customers in Egypt buy directly from the manufacturer, with engineers in the same time zone; elsewhere it is supplied directly or through distribution partners. More than 4,000 critical assets are monitored in more than 30 countries.