Power Quality Problems: Symptoms, Causes and What to Measure

Breakers trip, drives fault, transformers run hot. A symptom-by-symptom table of the power quality causes behind each one, and what to measure to prove it.

  • 3 min read
  • Inspector V4 · Portable V4
  • Updated Oct 2026

Most power quality problems are reported as something else: a drive that trips, a transformer that runs hot, a scanner that aborts, a capacitor bank that keeps blowing fuses. The symptom is real; the cause is often invisible because it lasts a few cycles or hides in the waveform. This guide maps the common symptoms to their usual power quality causes and to the measurement that proves or rules out each one.

Use it as a starting point, not a diagnosis. Several causes can produce the same symptom, which is exactly why you measure before you buy the fix.

Symptom, likely cause, what to measure

SymptomLikely power quality causesWhat to measure
Breakers, contactors or drives trip with no fault foundVoltage dips and short interruptions, transients, inrush currentRMS events with waveform capture at the equipment and at the incomer, time-stamped against the trip log. Dips explained
Production line stops for a few seconds, then restartsVoltage dips from network faults or large motor startsDip depth and duration, plotted against the ITIC and SEMI F47 curves
Variable speed drives trip on DC-bus overvoltageOscillatory transients from capacitor bank switching, swellsTransient capture with the time of each capacitor step. Transients explained
Transformer or neutral conductor runs hot; high neutral currentTriplen harmonics, unbalance, overloadHarmonic current spectrum per phase and in the neutral, K-factor, phase currents
Capacitor bank fuses blow or capacitors fail earlyHarmonic resonance between the bank and the supplyVoltage and current harmonics with the bank in and out of service. Resonance check
Motors run hot or fail before their rated lifeVoltage unbalance, harmonics, sustained undervoltageNegative-sequence unbalance, voltage THD and RMS at the motor terminals. Motors guide
Lights flickerVoltage fluctuations from welders, arc furnaces, compressors; interharmonicsFlicker severity Pst and Plt, rapid voltage changes, interharmonics
PCs, PLCs or controllers lock up or rebootDips and short interruptions, transients, neutral-to-earth voltageRMS events with waveforms, neutral-to-earth voltage at the equipment
UPS keeps transferring to batteryInput dips, frequency deviation on generator supply, high input distortionInput voltage events, frequency and THD at the UPS input. UPS guide
Power supplies, LED drivers and electronics fail earlyTransients, sustained overvoltage, high crest factorTransients, long-duration RMS levels, crest factor
MRI, CT or X-ray errors and aborted scansDips, transients, earthing problemsEvents with waveforms on the imaging feeder, earth current and earth resistance. Hospital imaging guide
Residual current devices trip without an obvious faultEarth leakage from filters and degrading insulation, harmonicsEarth leakage current trend over days, harmonic content
Power factor penalties on the electricity billLow displacement power factor, harmonics lowering true power factorTrue and displacement power factor, kVAR, current THD. Harmonics and power factor
Cables or busbars overheat at normal loadHarmonic currents, unbalanceRMS and harmonic current per phase and neutral, unbalance

Where to measure

Measure at two points if you can: at the equipment that fails and at the main incomer. If an event appears at both, it came from the supply. If it appears only at the equipment, it was created inside the site, by a neighbouring load, a loose connection or the equipment itself. That single comparison settles most arguments between a site and its utility.

How long to measure

At least one full week, because loads follow a weekly cycle and EN 50160 judges compliance on a week of 10-minute values. Intermittent problems — the trip that happens twice a month — need longer, which is where a permanent monitor beats a portable survey. The event that matters is often the one that happens after the analyzer has been removed.

Mistakes that hide the cause

  • Averaged data only. A one-minute average cannot show a 100 ms dip. You need event capture with the waveform.
  • Measuring after the event. A healthy reading today says nothing about last Tuesday.
  • No time link to the equipment. Without matching timestamps you cannot prove that a dip caused a trip.
  • One measurement point. You can see that the voltage dipped, but not where it came from.
  • Ignoring the earth. Earthing faults show up as nuisance trips and equipment errors, not as a voltage problem.

How Inspector helps

Inspector classifies dips, swells, interruptions, transients and rapid voltage changes with IEC 61000-4-30 methods, stores five cycles of waveform before and after every event, and records harmonics, flicker, unbalance and power factor continuously. Inspector V4 also measures earth current and earth resistance, so an earthing fault appears on the same timeline as the voltage event. Alerts reach the team by SMS, e-mail or app.

Not sure which instrument fits your problem? Try the model selector, look up a term in the power quality glossary, or describe the symptom to an engineer.

Next step

Tell us the failure. We will tell you what to measure.

Twenty minutes with an engineer who has instrumented hospitals, factories and data centres. No obligation, no slide deck.